
Custom Emergency Lights — Built to Code, Certified for Every Market
We design and manufacture customized LED emergency lights and exit signs for lighting brands, electrical distributors, contractors, and OEM clients worldwide. Every product is engineered to meet local safety codes from the start, so you pass inspection in North America, Europe, UK, Australia, Middle East, and Asia without rework.
Our factory in China handles full OEM/ODM: industrial design, optics, electronics, battery systems, plastic injection, metalwork, assembly, photometric testing, and certification filing.
Our Emergency Lighting Range
We produce all major categories, fully customizable for your brand and market:
- LED Emergency Downlights— recessed 3W to 12W, 1-3 hour autonomy
- Emergency Bulkhead Lights— IP65, IK10, for industrial and outdoor
- Exit Signs— edge-lit, panel, blade type, running man ISO or text EXIT, single/double face
- Twin Spot Emergency Lights— adjustable heads, commercial grade
- Emergency Battens and Linear— for corridors, car parks, warehouses
- Recessed Emergency Spotlights— low glare, architectural design
- Central Battery System Compatible Fixtures— DALI self-test, 24V, 110V, 230V
- Waterproof and Hazardous Location— IP66/IP67, ATEX option
All models available as maintained or non-maintained, with self-test function.
Why Choose Us as Your Emergency Light Factory
1. Design for Compliance First
We engineer to the exact standard of your market, not a generic version. This avoids costly failures.
- USA/Canada: UL924, NFPA 101, CSA C22.2 No.141, CEC Title 20
- Europe: EN 60598-2-22, EN 1838, CE LVD, EMC, RoHS, ERP
- UK: UKCA, BS 5266
- Australia/NZ: AS/NZS 2293, SAA, RCM
- Middle East: SASO IEC 60598-2-22, Civil Defense approval support
- Asia: CCC China, PSE Japan, KC Korea, BIS India
- Global: IECEE CB Scheme, ISO 9001 factory
2. True OEM Customization
Change housing shape, size, logo, lens, LED color temperature, lumen output, battery type LiFePO4 or NiMH, autonomy time, test button location, pictogram, and packaging. We offer private label and full ODM from sketch.
3. Reliable Battery and Electronics
We use Grade A LiFePO4 batteries for 3 years life, 500+ cycles. Options for self-test, DALI-2 monitoring, wireless test, and central monitoring systems. Drivers with overcharge, deep discharge, and short circuit protection.
4. Low MOQ and Fast Prototyping
Prototype in 7-10 days. Production MOQ from 200 pcs per model for custom branding. Standard models available from 50 pcs.
5. Full Testing In-House
Integrating sphere for lumen output, battery discharge test chambers, IP and IK test, thermal test, EMC pre-scan. We provide full test reports with every shipment.
Key Technical Options
- Power:3W, 5W, 6W, 8W, 12W LED
- Lumen Output:150lm to 1200lm emergency mode
- Autonomy:1 hour, 2 hours, 3 hours, 90 minutes UL
- Battery:LiFePO4 3.2V 1500-6000mAh, NiCd, NiMH
- Charging Time:24 hours standard, fast charge 12 hours option
- Input Voltage:100-277V AC universal, 220-240V, 120V
- IP Rating:IP20, IP40, IP54, IP65, IP66
- Mounting:recessed, surface, wall, suspended, pendant
- Function:manual test, self-test, DALI self-test, addressable
- Materials:PC, ABS, aluminum, fire-rated V0
Applications
- Commercial offices, schools, hospitals
- Hotels, shopping malls, airports
- Industrial warehouses, factories, car parks
- Residential towers, apartments, corridors
- Outdoor pathways, tunnels, marine environments
Our OEM Process for Emergency Lighting
- Define Market and Standard — UL924 or EN60598-2-22
- Design and DFM — housing, PCB, battery compartment
- Prototype — working sample with test report
- Certification — submit to TUV, UL, SAA using our pre-approved files
- Mass Production — SMT, assembly, 100 percent function and aging test
- Final QC — discharge test, lumen test, labeling check
Lead time: samples 7-12 days. Production 20-30 days.
FAQ — Custom Emergency Lights
Can you make exit signs with my language and pictogram?
Yes. We produce ISO 7010 running man, EXIT text, or custom language Arabic, French, Spanish. Single or double sided.
Do you offer self-test and DALI monitoring?
Yes. Standard self-test with LED indicator, and DALI-2 Type 1 emergency for BMS integration.
What is the difference between maintained and non-maintained?
Maintained stays on as normal light and switches to battery in power failure. Non-maintained only turns on during power failure. We build both.
Can you supply central battery system fixtures?
Yes. We manufacture 24V DC, 110V DC, and 230V AC central battery compatible downlights, bulkheads, and exit signs.
What warranty do you provide?
3 years on fixture, 2 years on battery LiFePO4, 1 year on NiMH. Extended warranty available.
Work With a Certified Emergency Lighting Partner
Compliance is not optional for emergency lights. Work with a factory that understands UL924, EN 1838, and AS/NZS 2293 from the design stage.
Send your specification or target market. We will return a compliant design, quotation, and certification plan within 24 hours.
Contact our project team:[email protected] WhatsApp: +86-19506675565